I have a weird problem with my m11a1. I suppose it all started when i placed silicon oil on the magazine where the gas goes out and i fired a few b's to lubricate the guns inernals. then i didnt use the gun for 3 weeks.
now, when i play with the gun, the bb's fly immediately downwards...as if there isnt enought firepower to propel the bb out. they only shoot out 2 feet! so i disassembled it and found that parts 46 - 48 (combined) may be the problem...when i press part in part 43, it moves so slow outward...very slow... could this be the problem? was it over lubricated? any feedback would be appreciated... thanks. |
|
April 25th, 2006, 21:59 | #2 |
Probably .
The rubber parts have probably swollen with oil, and are causing parts to stick. Maybe take-down and dry the parts, then let it sit for a while and try again. I recall the M11 requiring a tight watch on lube use. |
|
April 25th, 2006, 23:17 | #3 |
thanks for the reply. i'm having trouble disassembling part 48. it's hard to take out.
|
|
April 26th, 2006, 00:19 | #4 |
should the part 43 be moving fast when you release it after pressing?
|
|
|